Walk into most commercial buildings and they look the part. Clean lobbies. Working lifts. Lights on. But step into the plant room, pull out the service records, and ask to see the compliance certificates — and the story can change very quickly.
We’ve attended audits where the paperwork was either out of date, incomplete, or missing entirely, and one look at the condition of the plant areas confirmed what the files couldn’t hide: maintenance had been little more than lip service for years. The building looked fine. It wasn’t.
For property managers and managing agents across London and beyond, a commercial building maintenance checklist isn’t just a useful tool — it’s the difference between staying on the right side of the law and finding yourself exposed when something goes wrong.
Why the Legal Responsibility Lands Where You Might Not Expect
Before getting into what the checklist should contain, it’s worth being clear on something that catches people out: when it comes to legal liability for building compliance, the responsibility sits with the landlord — not the managing agent.
The clue, as our director Chris notes, is in the name. A managing agent manages. But when there’s an incident, a prosecution, or an insurance dispute, the spotlight falls on the building owner. That distinction matters enormously, because it means landlords need to be confident that whoever manages their buildings is actively maintaining and documenting compliance — not just assuming all is well.
That assumption, unfortunately, is more common than it should be.
There are certain legal maintenance requirements for commercial buildings in the UK that apply regardless of building size, age, or budget. These aren’t optional. If they’re not in place, the building is non-compliant — and the consequences can include enforcement notices, prosecution, invalid insurance, and in the worst cases, serious harm to occupants.
Here’s the core list every commercial property needs to have covered:
Fire Risk Assessment (FRA)
Required under the Regulatory Reform (Fire Safety) Order 2005. Must be carried out by a competent person and reviewed regularly, or whenever significant changes are made to the building or its use. The FRA isn’t a one-off — it needs to be kept current.
Asbestos Management — The Duty to Manage
One of the most serious statutory duties of all, and one of the most frequently overlooked. Under the Control of Asbestos Regulations 2012, the dutyholder for any non-domestic building has a legal “duty to manage” the asbestos within it. In practice that means an asbestos survey must have been carried out to identify and record where asbestos-containing materials are — or are presumed to be — an up-to-date asbestos register must be kept, and a written asbestos management plan must set out how the risk is being controlled, monitored and reviewed. The duty applies to virtually every commercial building constructed or refurbished before the year 2000, and it doesn’t end once the survey is done: the condition of any asbestos-containing materials has to be checked periodically and the register kept current. A building with no register and no management plan is non-compliant — regardless of whether the material has ever been disturbed.
Fixed Wire Testing (EICR — Electrical Installation Condition Report)
An inspection and test of the building’s fixed electrical installation. Recommended at least every five years for commercial premises, though high-usage environments may require more frequent testing. An out-of-date EICR is a serious compliance gap and a significant insurance risk.
Water Risk Assessment and L8 Compliance
Under the Health and Safety at Work Act 1974 and the Approved Code of Practice L8, any building with a water system that could present a legionella risk must have a written risk assessment and a documented water management scheme. This includes monitoring, temperature checks, and regular remedial actions — all of which need to be recorded.
Gas Certification
Any gas appliances, pipework, and flues must be inspected and certified annually by a Gas Safe registered engineer. The certificate needs to be current. We’ve seen buildings where the gas cert has lapsed without anyone noticing, because the system just kept working — until it didn’t.
Full Building Risk Assessment
Beyond fire, buildings should have a general risk assessment covering all significant hazards. This feeds into health and safety compliance under the Management of Health and Safety at Work Regulations 1999.
Signage
Often overlooked, but legally required. Fire exit signs, evacuation routes, fire equipment locations, and hazard notices all need to be in place and legible. Missing or faded signage is a compliance failure that shows up on every competent audit.

When the Building Looks Fine — But the Paperwork Doesn’t
One of the most consistent findings we make during compliance audits is the gap between how a building presents and what the documentation actually shows. And it tends to happen most in buildings that rely heavily on automated systems.
When maintenance is managed digitally or through automated scheduling, there can be a false confidence — the diary says the visit happened, so the assumption is that everything is in order. But automation doesn’t always mean accuracy. We’ve attended buildings where the following were either missing or significantly out of date: gas certificates, L8 water hygiene documentation, fire alarm service records, emergency lighting test sheets, dry riser inspection records, asbestos registers and management plans, and AOV (automatic opening vent) test documentation.
Some of these gaps might not trigger an incident for months or even years. But when they do, the absence of paperwork is as serious as the absence of the work itself. A dry riser that hasn’t been properly inspected and fails during a fire evacuation isn’t just a tragic outcome — it’s a prosecutable one.
Poor paperwork control is a building compliance failure in its own right. It’s not enough to carry out the work. The records need to exist, be accurate, and be accessible.
“If There Hasn’t Been an Incident, It Must Be Compliant”
Across the industry, the same patterns repeat.
- Chasing the Lowest Cost
Reducing PPM spend without understanding the consequences inevitably leads to increased reactive maintenance and long-term asset deterioration.
- Failing to Understandthe Asset
Without a clear picture of asset condition and performance, maintenance strategies are based on assumption—not fact.
- Assuming All Contractors Are Equal
The market is full of providers who sell well but fail to deliver, while more capable contractors are often overlooked.
- Avoiding Change
Even when performance is poor, many clients retain incumbent providers because:
- Tender processes are restrictive
- Decisions are often pre-determined
- Changing contractors carries risk if not managed correctly
There is a real skill to transitioning maintenance providers, and without it, clients often choose the safer—but less effective—option.

What PPM Should Actually Do
This is a view we encounter regularly, and it’s worth addressing directly.
The absence of an incident does not mean a building is compliant. It means you’ve been fortunate.
As Chris puts it: “If you don’t investigate and assume, then you could be an ass.” It’s blunt, but it’s accurate. We’ve seen buildings running without full compliance documentation for years — no incident to force a review, no audit to surface the gaps. Eventually, something changes: a fire, a legionella case, an insurance claim, a change of managing agent, or a due diligence exercise before a sale. And then the full picture comes into view.
At BASSE, we investigate. We check. And then we check again. That’s not pedantry — it’s the only defensible position.
How to Audit a Building’s Compliance When Taking It On
If you’re inheriting a building — or bringing in a new maintenance partner — the first step is a structured review of what’s actually in place, not what’s been assumed.
Our process starts with the basics: physical condition of the plant areas, review of service records, and checking whether statutory dates have been met. The plant room tells you a great deal before you’ve even opened a file. If equipment is visibly neglected, certificates are pinned to the wall with lapsed dates, or the service log is sparse, it’s a clear signal.
If there’s no usable paperwork trail, the only responsible course of action is to start again. As Chris explains: “Complacency is not allowed in British Justice.” You can’t carry forward someone else’s risk by accepting incomplete records. The safer position — legally and practically — is to establish a fresh baseline and build from there.
That typically means commissioning a full water risk assessment, booking an EICR if the last one is overdue or undocumented, updating the fire risk assessment, commissioning an asbestos management survey where the building predates 2000 and no register exists, and verifying that all service certification is current and legitimate.
Your Commercial Property Maintenance Checklist: A Practical Starting Point
Use this as a baseline for any commercial building maintenance compliance review:
- Fire Risk Assessment (FRA) — current, signed, reviewed within last 12 months or following any significant change
- Asbestos Management Survey — completed for any building constructed or refurbished before 2000, asbestos register current and accessible
- Asbestos Management Plan — written plan in place, condition of asbestos-containing materials reviewed and recorded
- Fixed Wire Testing (EICR) — within recommended frequency, certificate on file
- Water Risk Assessment — completed by a competent person, documented actions in place
- L8 Water Hygiene Monitoring — log books current, temperature records up to date
- Gas Safety Certificate — current, issued by Gas Safe registered engineer
- Fire Alarm Service Records — last service within 6 months, log book complete
- Emergency Lighting Test Records — monthly and annual tests logged
- Dry Riser Inspection Records — wet commission test annually, visual inspection 6-monthly
- AOV Testing Records — tested and documented to manufacturer’s schedule
- Full Building Risk Assessment — current and relevant to present use
- Signage — fire exits, evacuation routes, hazard notices all present and legible
- PAT Testing — where applicable, current certificates on file
This covers the core statutory and best-practice requirements UK property managers should follow for commercial building maintenance.
Additional items may apply depending on the building type, occupancy, and systems installed. Specialist plant, cooling towers, passenger lifts, and extraction systems have their own compliance obligations.
Getting Building Maintenance Compliance Right
The gap between a building that looks compliant and one that actually is compliant is almost always a documentation problem. Buildings get maintained, but records get neglected. We book and log work, but nobody checks whether statutory dates align, assessments are reviewed, or certifications meet requirements.
We work across commercial buildings throughout London, helping landlords and managing agents identify genuine compliance gaps and address them. That starts with an honest audit – not an assumption that the previous contractor had everything covered.
If you’re not confident your building is fully covered, or you’re taking over a property, we can help establish a proper compliance baseline.